The LFG103 indoor carbon monoxide transmitter uses a high-performance electrochemical sensor to measure the concentration of carbon monoxide in the environment, with rapid response, stable performance and high accuracy, wide power supply range. Perfect overvoltage and reverse connection protection, it has current & voltage or RS485 output signal, configurable relay action point, and has independent control alarm function. This product can be widely used in HVAC systems, kitchen restaurants workshops, underground parking lots, etc.
Features
* Imported high performance electrochemical sensor.
* A variety of output modes are optional, using LCD backlight display.
* Perfect overvoltage and reverse connection protection, high long-term reliability
* Configurable relay action point, can realize independent control/alarm function.
* The shell design is light and beautiful, and the standard 86 box installation method.
Transmitter
| Sensor | Electrochemical sensor with a typical lifetime of 5 years |
| Range | 0~100ppm/0~250ppm/0~400ppm |
| Accuracy | ±5%FS |
| Response Time(T90) | ≤60s |
| Preheat Time | 2min |
| Power Supply | 15~36VDC/24VAC+20% |
| Output Mode | 4~20mA & 0~10V |
| Relay | 1xSPDT 3A/30VDC 3A/250VAC |
| Working Environment | 0~50℃&15~90%RH (non-condensing)(continued) -10~60℃&0~95%RH (non-condensing)(Intermittent) |
| Storage Temperature | -10~60°C (long term storage: 5~30'C(Within 6 month)) |
| Degree of Protection | IP30 |
| Shell Material | PC |
Note: When AC power is used for RS485 output products, isolated 24VAC power should be used!



Imported high performance electrochemical sensor.
A variety of output modes are optional, using LCD backlight display.
Perfect overvoltage and reverse connection protection, high long-term reliability
Configurable relay action point, can realize independent control/alarm function.
The shell design is light and beautiful, and the standard 86 box installation method.
HVAC systems
Greenhouse
Kitchen
Restaurants
Workshops
Underground parking lots
Warehouse
Product Inquiry
18 Nov 2026
How to Select a Coolant Replenishment Pump for Liquid Cooling Systems17 Nov 2026
Peristaltic Pump Design: How Tubing, Motor Selection, and Material Compatibility Affect Performance07 Nov 2026
230VAC Shortened Diaphragm Pump: How to Solve Space Constraints in Commercial Equipment26 Oct 2026
LEFOO Connects with 50+ Customers from 20+ Countries and Regions at the 140th Canton Fair
English
français
Deutsch
Español
italiano
русский
português
العربية
Türkçe
Zulu 