LEFOO LFM53 differential pressure transmitter adopts a thermal micro-pressure core, and uses the micro-flow path integrated with the sensor chip to detect the air pressure by detecting the change of the flow rate of the thermal airflow. It has the characteristics of strong overload capacity, strong anti-electromagnetic interference ability, wide measurement range, and multi-signal output. Widely used in the detection of air or neutral gases, such as HVAC, process control, environmental control, clean room, or other detection systems that require differential pressure.
Features
* Imported thermal micro-pressure core body, sensitive to pressure
* Range as low as ±25Pa
* Overload pressure up to 2Bar
* Accuracy up to 0.5%F.S., strong stability, good repeatability
* Easy installation, insensitive to installation position
* Strong anti-interference ability, optional isolated output
Transmitter
| LEFOO High Accuracy Low Range Differential Pressure Transmitter LFM53 | ||
| Medium | air or neutral gas | |
| Pressure Range | ±25Pa, ±50Pa, ±100Pa | |
| Overpressure capacity | 2Bar | |
| Accuracy | ±25Pa, ±1Pa | |
| ±50Pa, ±1%F.S. | ||
| ±100Pa, ±0.5%F.S. | ||
| Operating temperature | -20℃~70℃ | |
| Storage temperature | -40℃~80℃ | |
| Temperature drift | 0.03%F.S./℃ | |
| Protection Level | IP65 | |
| Electrical connection | Four-wired | Six-wired |
| Output signal | RS-485 | 4~20mA/ 0~10VDC |
| Power supply | 9~30 VDC/24VAC±20% | 12~30 VDC/24VAC±20% |
| Pressure interface | Metal barbed interface,φ6.2mm | |
| Communication | RS-485 Standard interface, Modbus RTU protocol | |
| Certification | ROHS certification,EU CE certification | |
| Electromagnetic compatibility | EN 61326-1 | |

| Code and Description | Remark | ||||||||
| LFM53 | High Accuracy Low Range Differential Pressure Transmitter | Model | |||||||
| 1 | -25~25pa | Range | |||||||
| 2 | -50~50pa | ||||||||
| 3 | -100~100pa | ||||||||
| N | No display | Display | |||||||
| O | With display | ||||||||
| A | 4~20mA +0~10VDC( Simultaneous output) | Output type | |||||||
| E | RS-485 communication | ||||||||
| E1 | RS-485 communication(with isolation) | ||||||||
| LFM53 | 1 | O | E | Selection example | |||||
Imported thermal micro-pressure core body, sensitive to pressure
Range as low as ±25Pa
Overload pressure up to 2Bar
Accuracy up to 0.5%F.S., strong stability, good repeatability
Easy installation, insensitive to installation position
Strong anti-interference ability, optional isolated output
Air and Neutral gas pressure measuring
Noise environmental protection project bellows
Product Inquiry
03 Aug 2026
Engineering Factors That Shape Water Filter Booster Pump Performance in RO Systems01 Aug 2026
Optimizing Booster Pump Performance for Different RO Water Purification Systems30 Jul 2026
Enhancing RO Water Output Efficiency With Advanced Booster Pump Technology28 Jul 2026
Solving Viscous and Corrosive Fluid Handling Challenges With Stepper Peristaltic Pumps
English
français
Deutsch
Español
italiano
русский
português
العربية
Türkçe
Zulu 