TECHNICAL PARAMETER
Model series | Product number | Rated voltage (VDC) | Flow rate (L/min) | Current(A) | Head (m) | Power (w) | Debugging function |
LFP6012 | LFP6012-44060A | 12 | 44 | 3.5 | 6.0 | 42.0 | Optional PWM 0-5V speed regulation |
LFP6012-48070A | 12 | 48 | 4.0 | 7.0 | 48.0 | ||
LFP6012-50080A | 12 | 50 | 4.5 | 8.0 | 54.0 | ||
LFP6012-52080A | 12 | 52 | 5.6 | 8.0 | 67.2 | ||
LFP6012-55090A | 12 | 55 | 6.5 | 9.0 | 78.0 | ||
LFP5012-1 | LFP5012-08040A | 12 | 8 | 4 | 1.1 | 13.2 | FG Signal 0-5V speed regulation PWM speed regulation |
LFP5012-08070A | 12 | 8 | 7 | 1.3 | 15.6 | ||
LFP5012-10060A | 12 | 10 | 6 | 2.1 | 25.2 | ||
LFP5012-12080A | 12 | 12 | 8 | 3.1 | 37.2 | ||
LFP5012-13120A | 12 | 13 | 12 | 4.3 | 51.6 | ||
LFP5012-13150A | 12 | 13 | 15 | 4.3 | 51.6 | ||
LFP5012-2 | LFP5012-17060A | 12 | 17 | 6 | 1.4 | 16.8 | FG Signal 0-5V speed regulation PWM speed regulation |
LFP5012-20080A | 12 | 20 | 8 | 2 | 24 | ||
LFP5012-24140A | 12 | 24 | 14 | 4.4 | 52.8 | ||
LFP5012-22110A | 12 | 22 | 11 | 3.1 | 37.2 | ||
LFP5012-25115A | 12 | 25 | 11.5 | 3.2 | 38.4 | ||
LFP5012-25130A | 12 | 26 | 13 | 3.8 | 45.6 | ||
LFP5012-26145A | 12 | 26 | 14.5 | 4.5 | 54 | ||
LFP5012-3 | LFP5012-27040A | 12 | 27 | 4 | 1.5 | 18 | FG Signal 0-5V speed regulation PWM speed regulation |
LFP5012-32060A | 12 | 32 | 6 | 2.4 | 28.8 | ||
LFP5012-37080A | 12 | 37 | 8 | 3.8 | 45.6 | ||
LFP5012-40080A | 12 | 40 | 8 | 3.9 | 46.8 | ||
LFP5012-44080A | 12 | 44 | 8 | 5.1 | 61.2 | ||
LFP5012-45100A | 12 | 45 | 10 | 5.6 | 67.2 | ||
Ambient temperature | -20℃-40℃ | ||||||
Medium temperature | -20℃-60℃ | ||||||
Voltage range | 8~18 or 16~32 VDC (LFP50 series) | ||||||
Insulation class | F | ||||||
Protection class | IP55 or IP68 optional | ||||||
Life span | 20000H | ||||||
Interface | LFP5012-3, LFP6012: Outlet: DN20; Inlet: DN20 ; LFP5012-2: Outlet: DN15; Inlet: DN15 ; LFP5012-1: Outlet: DN8; Inlet: DN12. Custom supported. | ||||||
Test Conditions | BLDC hot water pump parameters test conditions: water inlet pipe DN20, water outlet pipe DN20, outlet pipe length 1m; when the water tank depth is 0.3m, the mini centrifugal pump is at the bottom of the water tank, and the flow rate, head and current are measured when the water outlet is 0.2m away from the water surface. | ||||||
Protective function | Anti-reverse connection protection, high and low voltage protection, idling protection, blocked rotor protection, phase loss protection | ||||||
Medium | Cool water, hot water and other clear water/fluid. |
BLDC WATER PUMP 24V are also available.