| Pressure Range | -100kPa~100kPa...2MPa | |||
| Overload Pressure | 1.5 times of the rated pressure | |||
| Destroying Pressure | 2 times the rated pressure | |||
| Accuracy① | +0.5%F.S、+1%F.S | |||
| Stability | <0.5%F.S/year | |||
| Working Temperature | -20~80°C | |||
| Storage Temperature | -20~80°C | |||
| Measured Medium | Gas or liquid compatible with 1Cr18Ni9Ti, PVDF, fluoroelastomer or perfluoroether rubber | |||
| Anti-corrosion pressure transmitter | ||||
| Electrical Properties | 2 wired | 3 wired | ||
| Output Signal | 4~20mA | 0.5~4.5V | 0~5V | 0~10V |
| Power Supply | 8~36VDC | 4.75~5.25VDC | 8~36VDC | 12~36VDC |
Electrical Connection | DIN43650A(Big Hirschmann), M12 waterproof Cable outlet | |||
| Display anti-corrosion pressure transmitter | ||||
| Electrical Properties | 2 wired | 3 wired | ||
| Output Signal | 4~20mA | 0~10V | ||
| Power Supply | 12~30VDC | 12~30VDC | ||
| Electrical Connection | DIN43650A(Big Hirschmann) | |||
| Enclosure Protection | IP65 | |||
| Pressure Connection | G1/2、M20*1.5 | |||
| Pressure Form | Gauge Pressure G | |||
| Certification | RoHS | |||
Note①: Measured at 25°C, including comprehensive accuracy of linearity, repeatability and hysteresis.


English
français
Deutsch
Español
italiano
русский
português
العربية
Türkçe
Zulu