LF56 series pressure switches are mainly used to control pressure of boiler or water tower regulating system. When the system pressure exceed the setting point, the switch will cut off the circuit for protection. With SPDT contact arrangement, LF56switch can detect the pressure change and shift the internal status accordingly to control the on/off of external circuits, which is available for the pressure control, limit and alarm of non-hazardous liquid, gas and steam.
Transmitter
Electrical rating | 15A125、250、480VAC; |
120 Vac\240 Vac | 8.0 AFL,48.0 ALR,10.0 A resistive l5.1 AFL,30.6 ALR,5.0 A resistive |
Contact arrangement | SPDT |
Contact resistance | smaller than 25mQ |
Electrical endurance | 50000 cycles |
Working media | air, water and oil |
Working pressure | 5-50 psi , pressure setting: 40psi |
Differential range | 6-14 psi |
Leakage | No leakage under the pressure 85psi for 1 minute |
Ambient temperature | -37℃~66℃ |
Mechanical endurance | 100000 cycles |
Adjustable pressure threshold setting.
Durable diaphragm and robust metal parts.
Precise pressure controll and 50000 cycle of use span.
Stable quality with many certifications for many countries.
Available for high temperature industrial boiler steam pressure control.
The pressurecontrol of boiler or water tower regulating system. limit and alarm of non-hazardous liquid, gas and steam.