Email Us

Specification of Ceramic Pressure Transmitter LFT2000

Technical parameter

LEFOO Ceramic Pressure Transmitter LFT2000
Measurement Range-100kPa-0.3MPa...6MPa, 0-0.3MPa...60MPa
Overload pressure1.5 times of full scales(Max.80Mpa)
Burst Pressure2 times of full scales(Max.90Mpa)
Accuracy±0.5%F.S., ±1.0%F.S.
Stability<0.5%F.S./Year
Working temperature-20~85℃
Storage Temperature-40~100℃
Medium CompatibilityAll corrosive mediums can be compatible with 1Cr18Ni9Ti, 304 stainless steel, Fluoroelastomer or NBR.
Output ModeTwo-wiredThree-wired
Output Signal4~20mA0.5~4.5V0~5V0~10V
Power Supply10-36VDC4.75-5.25VDC10-36VDC12-36VDC
Electrical Connection

Packard, DIN43650C (Small Hirschmann), DIN43650A (Big Hirschmann),

 M12 waterproof outlet, M12 aviation connector, GX12 aviation connector(three cores/four cores)

ProtectionIP67、IP65、IP54
Pressure connectionG1/4、NPT1/4、R1/4、BPS1/4、G1/2、7/16-20UNF、M20*1.5、M10*1、M14*1.5 etc.
Pressure FormGauge pressure G
CertificationSafety explosion-proof type E, RoHS, EU electrical safety standards CE


Dimension

2000size.jpg


Selection Guide

Code and description

Remarks

LFT2000

Ceramic Pressure Transmitter

Model


Range

-100kPa~0.3MPa...6MPa, 0~0.3MPa...60MPa

Measurement Range


A4

A4 = 4~20mA(Two-wired)

Output Mode

V05

V05 = 0.5~4.5V(Three-wired)

V0

V0 = 0~5V(Three-wired)

V10

V10 = 0~10V(Three-wired)


K

K = kPa

Unit

PP = psi
BB = Bar

M

M = MPa


0.5

0.5 = 0.5%F.S.

Accuracy

1.0

1.0 = 1.0%F.S.


P

P = Parkerd connector

Electrical connection

D

D = DIN43650C Small Hirschmann

D1

D1 = DIN43650A Big Hirschmann

M

M = M12 Waterproof outlet

C3C3=GX12 three cores aviation connector
C4C4=GX12 four cores aviation connector

H

H = M12 four cores aviation connector


G

G = G1/4

Pressure connection

N

N = NPT1/4

G2G2 = G1/2
M20M20 = M20*1.5
M14M14 = M14*1.5
M10
M10 = M10*1
UU = 7/16-20UNF

External thread

R

R = R1/4

B

B = BSP1/4

Cable length


1.0

1.0 = 1m

2.0

2.0 = 2m

3.0

3.0 = 3m



LFT2000

0-60MPa

A4

B

1.0

P

G

1.0


Example of Select