Email Us

Specification of General Type Flat Film Pressure Transducer LFT2700

Technical parameter

LEFOO General Type Flat Film Pressure Transducer LFT2700
Measurement Range-100Kpa…0~20KPa…35MPa
Overload Pressure1.5 time of full scales
Accuracy±0.5%F.S.,±1.0%F.S.
Stability<0.5%F.S./Year
Working Temperature-20~+85℃
Storage Temperature-40~+100℃
Measured MediumAll corrosive mediums can be compatible with 304/316 stainless steel, Fluoroelastomer or NBR.
Electrical propertiesTwo-wiredThree-wiredFour-wired
Output Signal4~20mA0.5~4.5V0~5V0~10VRS485
Power Supply10~36VDC4.75~5.25VDC10~36VDC12~36VDC10~30VDC
Electrical ConnectionDIN43650A (Big Hirschmann), M12 waterproof outlet, GX12 aviation connector (three cores/four cores)
Protection GradeIP65 / IP54
Pressure ConnectionG1/2、M20*1.5 etc.
Pressure FormGauge pressure G/ Absolute pressure A
CertificationRoHS, EU electrical safety standard CE


Dimension

2700size.jpg


Selection Guide


Code and Description

Remark

LFT2700

General Type Flat Film Pressure Transducer

Model


Range

-100Kpa…0~20KPa…35MPa

Measurement range



A4

A4 = 4~20mA(Two-wired)

Output mode

V05

V05 = 0.5~4.5V(Three-wired)

V0

V0 = 0~5V(Three-wired)

V10

V10 = 0~10V(Three-wired)

RS

RS485 = RS485(Four-wired)


K

K = kpa

Unit

PP = psi
BB = bar

M

M = Mpa


0.5

0.5= ±0.5%F.S.

Accuracy

1.01.0= ±1.0%F.S

D1

D1 = DIN43650A Big Hirschmann

Electrical connection

M

M = M12 Waterproof outlet

C3

C3 = GX12 three cores aviation connector

C4

C1 = GX12 four cores aviation connector

HH = M12 four cores aviation connector

G

G= G1/2

Pressure connection

MM = M20*1.5

1.0

1.0 = 1m

Cable length

2.0

2.0 = 2m

3.0

3.0 = 3m



LFT2700

0-60

A4

B

1.0

D1

G

1.0


Example of Select