Email Us

Specification of Liquid Temperature and Level 2 in 1 Transmitter LFT3200

Technical parameter


LEFOO Liquid Temperature and Level 2 in 1 Transmitter LFT3200
Pressure Range

0~1…200mH2O

Temperature Range

-20~100℃ (PT-100)

Overload pressure

1.5 times full scales

Accuracy

Pressure: ±0.5%F.S.

Temperature: ±2%F.S.

Stability

<0.5%F.S./year

Working Temperature

-20~+85℃

Storage Temperature-40~+100℃

Measured Medium

Fluids compatible with 304 and 316 stainless steel, PE, PV, Viton or NBR

Electrical Performance

Two-wired

Three-wired

Four-wired

Output Signal

4~20mA

0.5~4.5V

RS485

Power Supply

10~30VDC

4.75~5.25VDC

10~30VDC

Electrical connections

M14 waterproof outlet

Enclosure Rating

IP68

Pressure Interface

Throw-in Type

Pressure Form

Gauge Pressure G

Certification items

Safety explosion-proof type E, RoHS,   EU electrical safety standards CE



Dimension

3200size.jpg


Selection Guide

Code and DescriptionRemark
LFT3200Liquid Temperature and Level 2 in 1 TransmitterModel

Level Range0~1…200mH2ORange

Temperature Range-20 ~100℃

A4A4=4 ~ 20maOutput Mode
V05V05=0.5 ~ 4.5V
RSRS=RS485

MMeterUnit
CMCentimeter

0.50.5=0.5% F.S.Accuracy

MM=M12 waterproof outletElectrical Connection

1.01.0=1mCable Length
2.02.0=2m
3.03.0=3m


LFT32000-200-20 ~100℃A4M0.5M1.0
Selection Example