Email Us

Specification of Explosion-proof Pressure Transmitter LFT6200

Technical parameter

LEFOO Explosion-proof Pressure Transmitter LFT6200
Measurement Range-100KPa...0~10KPa...60MPa
Overload Pressure1.5 times of full scales
Accuracy±1.0%F.S.(-100KPa...0~1KPa...2KPa…60MPa)
±0.5%F.S.(-100KPa...0~3KPa...19KPa…60MPa)
±0.25%F.S.(-100KPa...0~20KPa…60MPa)
Stability<0.5%F.S./Year
Working Temperature-20℃~80℃
Storage Temperature-40~100℃
Medium CompatibilityGas or liquid compatible with 316L, 1Cr18Ni9Ti, VITON and NBR.
Electrical PerformanceTwo-wiredThree-wiredFour-wired
Output Signal4~20mA4~20mA+HART0~10VDCRS485
Power Supply10~30VDC14~36VDC10~36VDC
Insulation>100M Ω@500VDC
Electric Strength500VAC@60 second
Electrical ConnectionWaterproof outlet
Protection GradeIP67
Pressure ConnectionM20*1.5,G1/2


Dimension

LEFOO Model Select Table LFT6200


Selection Guide

Code and description

Remark

LFT6200

Explosion-proof pressure transmitter

Model


Range

-100KPa...0~10kPa...60MPa

Range


A4

A4 = 4~20mA(Two-wired)

Output mode

HARTHART = 4~20mA+HART(Two-wired)

V10

V10 = 0~10V(Three-wired)

RS

RS = RS485  (Four-wired)


K

K = kPa

Unit

PP = psi
BB = bar

M

M = MPa


1.01.0 = 1.0%F.S.

Accuracy

0.5

0.5 = 0.5%F.S.

0.250.25 = 0.25%F.S.

D

D =Directly outlet

Electrical connection


M

M = M20*1.5

Pressure connection

G2G2 = G1/2

1.0

1.0 = 1m

Cable length

2.0

2.0 = 2m

3.0

3.0 = 3m



LFT6200

0-60

A4

B

0.5

D

M

1.0


Selection example